[1]左漫漫,崔美荣,郭成莉,等.消化内镜废液积漏袋的设计和使用效果评价[J].军事护理,2023,40(06):109-111.[doi:10.3969/j.issn.2097-1826.2023.06.026]
 ZUO Manman,CUI Meirong,GUO Chengli,et al.Design and Application of the Digestive Endoscopy Waste-fluid Collection Bag[J].Nursing Journal Of Chinese People's Laberation Army,2023,40(06):109-111.[doi:10.3969/j.issn.2097-1826.2023.06.026]
点击复制

消化内镜废液积漏袋的设计和使用效果评价
分享到:

《军事护理》[ISSN:2097-1826/CN:31-3186/R]

卷:
40
期数:
2023年06期
页码:
109-111
栏目:
技术与方法
出版日期:
2023-06-15

文章信息/Info

Title:
Design and Application of the Digestive Endoscopy Waste-fluid Collection Bag
文章编号:
2097-1826(2023)06-0109-03
作者:
左漫漫崔美荣郭成莉潘淑芬顾倍源辛磊刘翠
(海军军医大学长海医院 消化内镜中心,上海 200433)
Author(s):
ZUO ManmanCUI MeirongGUO ChengliPAN ShufenGU BeiyuanXIN LeiLIU Cui
(Digestive Endoscope Center,Changhai Hospital,Naval Medical University,Shanghai 200433,China)
关键词:
内镜 内窥镜逆行胰胆管造影术 废液
Keywords:
endoscopy endoscopic retrograde cholangiopancreatography waste fluid
分类号:
R473.57; R823
DOI:
10.3969/j.issn.2097-1826.2023.06.026
文献标志码:
A
摘要:
目的 设计消化内镜废液积漏袋,以期为减少术中废液污染情况提供有效工具。方法 2020年设计消化内镜废液积漏袋,采用便利抽样法选取2021年10月至2022年1月某院消化内镜中心行胰胆管造影术(endoscopic retrograde cholangiopancreatography,ERCP)操作的80例患者为研究对象,并依据随机数字法将其分为对照组和观察组,每组40例。对照组术中使用一次性PE手套收集阀门口废液,而观察组使用手术废液积漏袋。比较两组单位时间内收集废液量及废液污染情况评分。结果 对照组与观察组单位时间内收集废液量分别为3.55(3.2,4.3)ml/h和5.5(4.5,5.8)ml/h,差异有统计学意义(P<0.001)。观察组废液污染评分以0~1分为主,约占92.5%,其废液污染情况明显优于对照组,差异亦有统计学意义(Z=-5.763,P<0.001)。结论 手术废液积漏袋的使用可有效收集ERCP中产生的废液,减少术中废液手术室环境污染情况的发生,值得推广应用。
Abstract:
Objective To design a new digestive endoscopy waste-fluid collection bag in Endoscopic Retrograde Cholangiopancreatography(ERCP),and to provide an effective tool for reducing intraoperative waste liquid contamination.Methods The digestive endoscopy waste-fluid collection bag was designed in 2020. Eighty patients who underwent ERCP operation in a Digestive Endoscope Center from October 2021 to January 2022 were selected by convenience sampling method,and were divided into control group and observation group according to random number method,with 40 patients in each group.In the control group,disposable PE gloves were used to collect the valve port waste liquid,while the observation group used the surgical waste-fluid collection bag.The amount of waste liquid collected per unit time and the score of waste liquid staining were compared between the two groups.Results The amount of waste liquid collected per unit time in control group and observation group was 3.55(3.2,4.3)ml/h and 5.5(4.5,5.8)ml/h,respectively,and the difference was statistically significant(P<0.001).The waste liquid staining score of the observation group was mainly 0-1,accounting for about 92.5%,and the waste liquid staining situation of the observation group was significantly better than that of the control group,the difference was statistically significant(Z=-5.763,P<0.001).Conclusions The digestive endoscopy waste-fluid collection bag can effectively collect waste fluid generated during ERCP operation and reduce the occurrence the environmental staining of the operating room,which is worthy of popularization and application.

参考文献/References:

[1] 李鹏,王拥军,王文海.中国经内镜逆行胰胆管造影术指南(2018版)[J].临床肝胆病杂志,2018,34(12): 2537-2554.
[2] 国家消化内镜专业质量控制中心,中国医师协会内镜医师分会,中华医学会消化内镜学分会.中国消化内镜诊疗中心安全运行指南(2021)[J].中华消化内镜杂志,2021,38(6): 421-425.
[3] 王淑萍,张倩,许丽君,等. 内镜下治疗十二指肠乳头括约肌切缘出血的护理配合技巧[J]. 解放军护理杂志, 2022,39(1):88-89,96.
[4] RUSTAGI T,JAMIDAR P A.Endoscopic retrograde cholangiopan creatography-related adverse events:general overview[J].Gastrointest Endosc Clin N Am,2015,25(1):97-106.
[5] COTTON P B,EISEN G,ROMAGNUOLO J,et al.Grading the complexity of endoscopic procedures:results of an ASGE working party[J].Gastrointest Endosc,2011,73(5):868-874.

备注/Memo

备注/Memo:
【 收稿日期 】2022-06-17【 修回日期 】2023-03-29
【 基金项目 】长海医院“攀峰234”临床创新项目(2019YXK009)
【 作者简介 】左漫漫,本科,护师,电话:021- 31161375
【 通信作者 】刘翠,电话:021-31161376